Skip to content
Open 24/7 Plantation & nearby
Plantation Locksmith logo Español (954) 606-9052

Change Your Working Key

How to Reset a Kwikset SmartKey Lock

Call (954) 606-9052 for help with a Kwikset SmartKey reset that has left your lock unusable. We rekey and repair locks at your location, open 24/7, and typically arrive in 15-20 minutes. Changing a working key yourself? Start with the door open.

  • Mobile locksmith service
  • At least a 6-month warranty on parts and labor
  • Hablamos español

Prepare Your Kwikset SmartKey Lock for a Key Change

  • A current key that turns — Start only with a key that currently operates your lock. This procedure changes which physical key the cylinder accepts; it does not restore access when every working key is missing.
  • A compatible replacement key — Have the new key beside you before removing the current one. SmartKey cylinders do not all accept the same key type, so a key that fits another door is not automatically compatible with this cylinder.
  • The supplied accessory — Have the manufacturer-supplied accessory that fits the small SmartKey opening beside the keyhole. Do not begin the key-change sequence with that item missing, and do not push an improvised object into the opening.
  • The correct direction for your cylinder — The steps below cover the common clockwise-start procedure. Some SmartKey versions use different turn directions; check your model’s manual through [Kwikset support](https://www.kwikset.com/support) before starting if its instructions differ.

Kwikset SmartKey Reset With Your Current Working Key

  1. Open and secure the door — Keep the door fully open and prevent it from swinging shut. Extend a deadbolt into its locked position; set a keyed knob or lever to locked.
  2. Turn the current key clockwise — Insert the working key completely. Turn it 90 degrees clockwise—a quarter turn—and leave it there.
  3. Insert and remove the supplied accessory — Press it fully and firmly into the small SmartKey opening beside the keyhole. You may feel a click. Withdraw it while leaving the key turned.
  4. Exchange the keys — Remove the current key without changing the cylinder’s position. Insert the replacement completely, until its shoulder meets the recess in the cylinder face.
  5. Turn the replacement counterclockwise — Rotate it 180 degrees counterclockwise—a half turn. Avoid pushing or pulling while turning.
  6. Turn back and check retention — Rotate 180 degrees clockwise. Gently pull the key; it should stay in the cylinder at this position.
  7. Return to the starting position — Turn 90 degrees counterclockwise, then remove the key. Stop if removal or rotation requires force.
  8. Test before closing — Reinsert the new key and operate the lock with the door open. Check that the former key no longer operates it.

Need help now? (954) 606-9052

Why Your SmartKey Key Will Not Turn After Rekeying

The replacement was not fully inserted

Kwikset identifies incomplete insertion as a common cause of a misprogrammed cylinder. If neither key now operates the lock, stop the owner procedure and arrange professional help.

The key moved while turning

Pulling outward or pressing inward, upward, or downward during rotation can disrupt rekeying. Turn with steady rotational pressure rather than using the key to move the door.

The new key is incompatible

A different key profile cannot become compatible through repeated resets. If the replacement does not seat completely, stop before attempting the programming turns.

The key comes out while turned

Removal during the retention check is a failed test, not a finished reset. Keep the door open and leave the cylinder for professional attention instead of relying on that key.

When a SmartKey Reset Needs a Locksmith

Stop and call a professional when the original key will not turn, both keys stop operating the cylinder, or the replacement pulls out during the retention check. A broken key, persistent binding, or a cylinder that turns in only one direction also needs attention before you depend on the door for security. We offer Kwikset SmartKey rekeying and repair, along with broken key extraction and lock replacement. For a failed reset or damaged lock, contact us for locksmith service rather than forcing another turn.

Need help now? (954) 606-9052

Frequently asked questions

Will rekeying my SmartKey lock stop the old key from working?

Yes. A successful rekey changes the physical key the cylinder accepts, so the previous key should no longer operate it. Test both keys before closing the door; if the former key still works, the change is incomplete and we offer lock rekeying.

Does a SmartKey reset also change my keypad code?

No. Rekeying changes the mechanical key cylinder, while keypad programming controls electronic entry codes. If your goal is to remove someone’s access, changing the physical key alone does not remove their existing keypad code.

Can I make several SmartKey locks use one existing key?

Yes, when each cylinder accepts the same compatible key type. Each lock needs its own rekeying sequence, using the key that currently operates that particular cylinder. We offer lock rekeying when you want matching keys without replacing every lock.

Should I replace my SmartKey lock after an unsuccessful reset?

An unsuccessful reset does not automatically mean the entire lock needs replacement. Incorrect key insertion or movement during rekeying can leave the cylinder misprogrammed. We offer both lock repair and lock change services, so a failed key change does not limit you to replacing the whole lock.

Key Still Stuck After Rekeying?

Call Plantation Locksmith at (954) 606-9052 for lock rekeying, broken key extraction, or lock repair.

(954) 606-9052 Get a quote